2 years long-term follow-up optical coherence tomographic findings compared with 9 months after implantation of everolimus-eluting stents |
연세대학교 원주의과대학 원주기독병원 |
이준원1, 이지현2, 김우택3, 윤영진4, 안성균5, 안민수6, 김장영7, 유병수8, 이승환9, 윤정한10, 최경훈11 |
Background and Objectives:
Late or very late stent thrombosis after drug-eluting stent (DES) implantation may be related with incomplete neointimal coverage. Optical coherence tomography (OCT) is valuable modality for the assessment of stent strut coverage. We evaluated long-term (2 years) effect of everolimus-eluting stent (EES) for tissue coverage and apposition of stents using OCT compared with 9 months follow-up results.
Subjects and Methods:
OCT was evaluated in 30 EESs (28 patients) diagnosed as acute coronary syndrome. The percent difference of uncovered struts was analyzed according to follow-up period (9 month vs. 2 year).
Results:
Group I (short-term group, 22 lesions in 21 patients) and Group II (long-term group, 8 lesions in 7 patients) were included in the analysis. The stent diameter and stent length were no significant differences in both groups (2.94 ± 0.35 vs. 3.06 ± 0.28, p=0.398; 24.27 ± 8.28 vs. 31.13 ± 13.00, p=0.097, respectively). The area of neointimal coverage was significantly higher in Group II (11.5 ±4.1 vs. 18.5 ± 5.9, p=0.012) and the percent of uncovered struts was significantly reduced in Group II (9.7 ± 7.0 vs. 3.0 ± 5.2, p=0.019). No differences was shown in malapposed stent struts between both groups (3.2 ± 8.8 vs. 0.8 ± 1.8, p=0.441).
Conclusions:
Frequent incomplete neointimal coverage was still observed even in new generation stent (EES) at 9 months. But, uncovered stent struts were significantly reduced at 2 years follow-up. Further studies are required to determine the clinical significance of this finding.
|
|
Group I n = 22 |
Group II n = 8 |
p |
Stent diameter, mm |
2.94 ± 0.35 |
3.06 ± 0.28 |
0.398 |
Stent length, mm |
24.27 ± 8.28 |
31.13 ± 13.00 |
0.097 |
Number of analyzed section, n |
599 |
199 |
|
Number of analyzed struts, n |
6251 |
1821 |
|
Lumen area, mm2 |
169.2 ± 69.2 |
154.7 ± 35.9 |
0.464 |
Stent area, mm2 |
191.4 ± 78.7 |
189.9 ± 39.8 |
0.947 |
NIH area, mm2 |
11.5 ± 4.1 |
18.5 ± 5.9 |
0.012 |
Malapposed struts, n |
3.2 ± 8.8 |
0.8 ± 1.8 |
0.441 |
Uncovered struts, % |
9.7 ± 7.0 |
3.0 ± 5.2 |
0.019 |
|
|
|